Abstract
Background: Retention of implant-supported crowns is a critical factor influencing the long-term success of implant prostheses. The choice of luting cement plays an important role in determining the retentive strength, retrievability, and clinical performance of cement retained implant restorations.
Aim: To comparatively evaluate the retention of implant-supported crowns cemented with zinc phosphate cement, resin cement, and resin-modified glass ionomer cement using a universal testing machine in an in vitro setting.
Materials and Methods: Thirty implant–abutment–crown assemblies were fabricated and divided into three groups (n = 10) based on the luting cement used: Group I—zinc phosphate cement, Group II—resin cement, and Group III—resin-modified glass ionomer cement. Standardized full-coverage metal crowns were cemented onto prefabricated titanium abutments following manufacturer instructions. All specimens were stored in distilled water at 37°C for 24 hours. Retention was evaluated by applying a tensile load along the long axis of the implant using a universal testing machine at a crosshead speed of 1 mm/min until crown dislodgement occurred. The maximum pull-out force required was recorded in Newtons and statistically analyzed.
Results: The highest mean retentive strength was observed in the resin cement group, followed by resin-modified glass ionomer cement, while zinc phosphate cement demonstrated the lowest retention. Statistical analysis revealed a significant difference in pull-out force values among the three groups (p < 0.05).
Conclusion: Within the limitations of this in vitro study, resin cement provided superior retention for implant-supported crowns compared to resin-modified glass ionomer cement and zinc phosphate cement. Selection of luting cement should consider the balance between retention requirements and the need for retrievability in implant prosthodontics.
KeywordsImplant supported crowns; Luting cements; Retention; Pull-out force; In vitro study
The full text of this article is available as a PDF.
Download PDF- Jha A, Aher V, Lath P, Khangembam M, Nishant, Pani P, Singh U. Knowledge and awareness of dental implants as a treatment choice in the adult population in North India: A hospital-based study. Natl J Maxillofac Surg. 2021 May-Aug;12(2):244-249.
- Chakraborty N, Almudarris BA, Gautam P, Laddha R, Giri TK, Patel VD. Patient satisfaction and quality of life outcomes following dental implant placement. J Pharm Bioallied Sci. 2024 Dec;16(Suppl 4):S3338-S3340.
- Jain JK, Sethuraman R, Chauhan S, Javiya P, Srivastava S, Patel R, Bhalani B. Retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches: A systematic review with meta-analysis. J Indian Prosthodont Soc. 2018 Jul-Sep;18(3):201-211.
- Vigolo P, Mutinelli S, Givani A, Stellini E. Cemented versus screw-retained implant-supported single-tooth crowns: A 10-year randomised controlled trial. Eur J Oral Implantol. 2012;5:355-364.
- Sathyanarayan S, Balavadivel T, Guru RC, Sande AR, Rajendran V, Sengottaiyan AK. Retention of various luting agents used with implant-supported crowns. J Pharm Bioallied Sci. 2021 Nov;13(Suppl 2):S1206-S1209.
- Clayton GH, Driscoll CF, Hondrum SO. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Int J Oral Maxillofac Implants. 1997;12:660-665.
- Sheets JL, Wilcox C, Wilwerding T. Cement selection for cement-retained crown technique with dental implants. J Prosthodont. 2008;17:92-96.
- Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: A critical review. Int J Oral Maxillofac Implants. 2003;18(5):719-728.
- Mansour A, Ercoli C, Graser GN, Tallents RH, Moss ME. Comparative evaluation of casting retention using different cements. J Prosthet Dent. 2002;87(2):144-149.
- Bernal G, Okamura M, Munoz CA. The effects of abutment taper, length, and cement type on resistance to dislodgement of cement-retained implant-supported restorations. J Prosthodont. 2003;12(2):111-115.
- Agar JR, Cameron SM, Hughbanks JC, Parker MH. Cement removal from restorations luted to titanium abutments with simulated subgingival margins. J Prosthet Dent. 1997;78(1):43-47.
- Ramp MH, Dixon DL, Ramp LC, Breeding LC, Barber LL. Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent. 1999;81(5):510-514.
- Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent. 1997;77(1):28-35.
- Misch CE. Contemporary Implant Dentistry. 3rd ed. St. Louis: Mosby Elsevier; 2008. p. 557-570.
Looking up citing articles…
Copyright © 2025 Academia Journal of Medicine